2 terminals 2, Terminals 2, Control mode – Lenze 8400 motec User Manual
Page 248: 7technology applications
7
Technology applications
7.4
TA "Switch-off positioning"
248
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.4.4.2
Terminals 2
Related topics:
Truth table for activating the pre-switch off
( 240)
Connection
Assignment
Connection
Assignment
DI1
FB
.bStop1
RFR
-
DI2
FB
.bStop2
AU/AI
LA_NCtrl.nMainSetValue_a
10 V ≡ 100 % reference speed (
)
DI3
LA_NCtrl.bRLQCw
FB
.bInputSel1
DI4
LA_NCtrl.bRLQCcw
FB
.bInputSel2
NO, COM
LA_NCtrl.bDriveFail
DI5
LA_NCtrl.bBrkRelease
DO1
LA_NCtrl.bDriveReady
NO
COM
AR
AU/AI
GND
RFR
DI1
DI2
DI3
DI4
DI5
DO1
24O
GND
X3/X4
Speed setpoint
Enable controller / reset error message
Stop function 1
Stop function 2
Cw rotat. / QSP / selection: switch-off pos. 1
Ccw rotat. / QSP / selection: switch-off pos. 2
Manual release of the holding brake
DriveFail
DriveReady