Function library

12.11

L_JogCtrlExtension_1

474

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.11

L_JogCtrlExtension_1

This function extension is available from version 05.00.00!

This FB is connected upstream to the

L_NSet_1

ramp function generator/setpoint generator to

implement a switch-off positioning at limit switch.

• Detailed information on this operating mode can be found in the description of the

TA "Switch-

off positioning"

.

( 238)

Inputs

Identifier

Data type

Information/possible settings

bInputSel1

bInputSel2

BOOL

Activation of the bSlowDown1/bStop1, bSlowDown2/bStop2 and bSlowDown3/

bStop3 signal pairs according to the

Truth table for activating the pre-switch off

bRfgIn

BOOL

Ramping down the ramp function generator in the downstream FB

L_NSet_1

according to the

Truth table - switch-off positioning

bJog1In

bJog2In

BOOL

Selection inputs for setting fixed speeds in the setpoint generator

• If the pre-switch off is inactive (bInputSel1 and bInputSel2 are both set to FALSE),

the two control signals are output one-to-one at the bJog1Out and bJog2Out

outputs.

• To achieve the desired behaviour (starting at high speed, pre-switch off at low

speed), both inputs must be set to TRUE.

• Fixed setpoint 2 must be less than fixed setpoint 3!

Otherwise, the drive will start at a low speed and accelerate after the pre-switch

off.

bSlowDown1

bSlowDown2

bSlowDown3

BOOL

Activation of the fixed setpoint 2 in the downstream FB

L_NSet_1

• These inputs only fulfil a function if they have been activated via bInputSel1 and

bInputSel2 previously (see

Truth table for activating the pre-switch off

).

bStop1

bStop2

bStop3

BOOL

Ramping down of the ramp function generator in the downstream FB

L_NSet_1

• These inputs only fulfil a function if they have been activated via bInputSel1 and

bInputSel2 previously (see

Truth table for activating the pre-switch off

).

/B-RJ&WUO([WHQVLRQB

E,QSXW6HO

E,QSXW6HO

E5IJ,Q

E-RJ,Q

E5IJ2XW

E-RJ2XW

E-RJ2XW

E-RJ,Q

E6WRS

E6ORZ'RZQ

E6WRS

E6ORZ'RZQ

E6WRS

E6ORZ'RZQ

'08;













&75/

&

&

&

&

&

&

&

&

&

&

&

(GJHGHWHFW

&

&

&

&

&

&

E5IJ2XW

E-RJ2XW

E-RJ2XW

25

$1'

$1'



/B-RJ&WUO([WHQVLRQBE5IJ2XW

(QWU\LQVHOHFWOLVW



/B-RJ&WUO([WHQVLRQBE-RJ2XW



/B-RJ&WUO([WHQVLRQBE-RJ2XW

&RQILJXUDWLRQ

SDUDPHWHUV