3 terminals 11, 4 terminal 16, Terminals 11 – Lenze 8400 motec User Manual

Page 216: Terminal 16, 7technology applications

Advertising
background image

7

Technology applications

7.2

TA "Actuating drive speed"

216

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.2.3.3

Terminals 11

7.2.3.4

Terminal 16

Connection

Assignment

Connection

Assignment

DI1

LA_NCtrl.bSetSpeedCcw

RFR

LA_NCtrl.bFailReset

DI2

LA_NCtrl.bSetDCBrake

AU/AI

LA_NCtrl.nMainSetValue_a

10 V ≡ 100 % reference speed (

C00011

)

DI3

LA_NCtrl.bMPotUp

DI4

LA_NCtrl.bMPotDown

NO, COM

LA_NCtrl.bDriveFail

DI5

LA_NCtrl.bBrkRelease

DO1

LA_NCtrl.bDriveReady

NO

COM

AR

AU/AI

GND

RFR

DI1

DI2

DI3

DI4

DI5

DO1

24O

GND

X3/X4

Speed setpoint

Enable controller / reset error message

Direction of rotation CCw

Manual DC-injection braking (DCB)

increase speed

decrease speed

Manual release of the holding brake

Motor potentiometer

DriveFail

DriveReady

Connection

Assignment

Connection

Assignment

DI1

LA_NCtrl.bJogSpeed1

RFR

LA_NCtrl.bFailReset

DI2

LA_NCtrl.bJogSpeed2

AU/AI

LA_NCtrl.nMainSetValue_a

10 V ≡ 100 % reference speed (

C00011

)

DI3

LA_NCtrl.bRLQCw

DI4

LA_NCtrl.bRLQCcw

NO, COM

LA_NCtrl.bDriveFail

DI5

LA_NCtrl.bBrkRelease

DO1

LA_NCtrl.bDriveReady

X3/X4

NO

COM

AR

AU/AI

GND

RFR

DI1

DI2

DI3

DI4

DI5

DO1

24O

GND

Speed setpoint

Enable controller / reset error message

Selection of fixed setpoint 1/3

Selection of fixed setpoint 2/3

Cw rotation - quick stop

CCw rotation - quick stop

Manual release of the holding brake

DriveFail

DriveReady

Advertising