Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

175

5

Motor control (MCTRL)

5.14

Monitoring

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Tip!

• If forced ventilated motors are used, a premature response of the overload threshold can

be avoided by deactivating this function if necessary (

C00606

= "0: No Reaction").

• The current limits set in

C00022

and

C00023

influence the I

2

xt calculation only in an

indirect way. However, the operation of the motor at maximum possible load can be

averted.

Defining current and speed limits

( 94)

Note!

If the motor is operated by two drives with different rated currents, an adapted value has

to be entered into

C00120

.