Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

407

11

Parameter reference

11.2

Parameter list | C00981

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00981

C00982

C00984

C00987

Parameter | Name:

C00981 | Energy display

Data type: INTEGER_32

Index: 23594

d

= 5C2A

h

Display parameter for an energy analysis in the prevailing application. From this, decisions can be deduced whether

a measure for energy optimisation is economic.

• The values are saved to the device by switching off the mains and cannot be reset.

Display range

(min. value | unit | max. value)

0.00

kWh

21474836.47

Subcodes

Info

C00981/1

Output energy in motor mode

C00981/2

Output energy in generator mode

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00982 | VFC-ECO: Minimum voltage V/f ramp

Data type: UNSIGNED_8

Index: 23593

d

= 5C29

h

Voltage ramp for cancelling V-Sub with energy-saving V/f characteristic control (

VFCplusEco

)

Setting range

(min. value | unit | max. value)

Lenze setting

0.1

s

5.0 0.5 s

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00984 | Motor flux Add

Data type: INTEGER_16

Index: 23591

d

= 5C27

h

From version 02.00.00

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

%

199.9 20.0 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00987 | Inverter motor brake: nAdd

Data type: INTEGER_16

Index: 23588

d

= 5C24

h

From version 02.00.00

Speed lift which is connected in pulses to the brake rampe when the motor is braked.

Inverter motor brake

Setting range

(min. value | unit | max. value)

Lenze setting

0

rpm

1000 80 rpm

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1