Configuring the list by means of parameterisation, 8basic functions – Lenze 8400 motec User Manual

Page 266

Advertising
background image

8

Basic functions

8.1

Parameter change-over

266

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Importing/exporting the list
For cross-device reuse of the configured WriteParamList, you can click on the Export list and Import

list buttons to save the parameter selection as an *.epc file and then to re-import the saved *.epc file

into another drive controller 8400.

8.1.2

Configuring the list by means of parameterisation

The following application example shows the necessary procedure for configuring the list without

using the »Engineer« parameterisation dialog.
Task:
The parameters

C00012

,

C00026/1

,

C00027/1

and

C00222

to

C00224

are to be written.

Compiling the parameter list
In

C01085/1 ... n

, specify the above-named parameters in the <Code>,<Subcode> format:

C01085/1

= 12.000

C01085/2

= 26.001

C01085/3

= 27.001

C01085/4

= 222.000

C01085/5

= 223.000

C01085/6

= 224.000

C01085/7 ... n

= 0.000 (no parameter)

Entering values for the parameters (value set 1)
In

C01086/1 ... n

, specify the values to be used to describe the selected parameters. The values are

entered according to the scaling format/scaling factor of the respective parameter.

C01086/1

= <value> for list entry 1 (in our example: for parameter

C00012

)

C01086/2

= <value> for list entry 2 (in our example: for parameter

C00026/1

)

C01086/3

= <value> for list entry 3 (in our example: for parameter

C00027/1

)

• etc.

These values are used for writing if the bSelectWriteValue_1 input is not assigned or set to FALSE.

Entering further different values for the parameters (value set 2)
If required, you can set another set with values in the same manner in

C01087/1 ... n

which serve to

write the parameters.

Note!

Gaps in the parameter list (setting = 0.000) are permissible and are skipped in the

process.
Invalid parameter entries are not accepted when being entered.

Advertising