Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

301

9

Diagnostics & error management

9.8

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Error ID

8-bit value (0 ... 255) for error identification within the error subject area.

Tip!
All possible 16-bit error numbers are listed in the table entitled "

Short overview (A-Z)

" in the

second column.

( 302)

9.8.3

Reset error message

An error message with the response "Fault", "Trouble", or "Warning locked" must be explicitly reset

(acknowledged) after the cause of the error has been eliminated.
There are several options to reset (acknowledge) a pending error message:

• Execute the "reset error" device command: Set

C00002/19

= "1"

• Set the bFailReset control input to TRUE

• In the Lenze setting of

C00701/2

, this input is connected to the digital input RFR (controller

enable) so that a possibly existing error message is reset together with the controller enable

(if the cause for the fault is eliminated).

• "ResetFault" command via fieldbus: Set bit 7 = "1" in the control word
• When an online connection to the controller has been established, change to the Diagnostics

tab of the »Engineer« and click the Reset error message button.

8

14

Bit15

0

7