11 parameter reference – Lenze 8400 motec User Manual

Page 332

Advertising
background image

11

Parameter reference

11.2

Parameter list

332

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00002/14

0: Off / ready

Reserved

C00002/15

0: Off / ready

Reserved

C00002/16

1: On / start

Enable controller

"1" ≡ Enable controller

"0" ≡ Inhibit controller

C00002/17

0: Off / ready

Activate quick stop

"1" ≡ Activate quick stop

"0" ≡ Deactivate quick stop

C00002/18

0: Off / ready

Reserved

C00002/19

0: Off / ready

Reset error

• After the reset (acknowledgement) of the current

error, further errors may be pending which must also

be reset.

• Details of the currently pending error are displayed in

C00166

.

C00002/20

0: Off / ready

Reserved

C00002/21

0: Off / ready

Delete logbook

• All entries in the logbook of the controller are deleted.

• In the logbook, information on the error history is

saved.

C00002/22

0: Off / ready

Reserved

C00002/23

0: Off / ready

Motor parameter identification

• This device command serves to carry out automatic

motor parameter identification.

• The device command is only executed when the drive

controller is in the "SwitchedOn" status.

• In order to identify the motor parameters, the

controller must be enabled after this device

command.

Automatic motor parameter identification

C00002/24

0: Off / ready

Reserved

C00002/25

0: Off / ready

Reserved

C00002/26

0: Off / ready

CAN reset node

• Reinitialise CAN interface of the communication unit

CANopen.

• Required when changing the baud rate, node address,

or identifiers.

C00002/27

0: Off / ready

Device search function

From version 04.00.00

• This device command serves to optically locate a

controller connected online (e.g. for maintenance

work).

Device search function

C00002/28

0: Off / ready

Reserved

C00002/29

0: Off / ready

Reserved

C00002/30

0: Off / ready

Reserved

C00002/31

0: Off / ready

Reserved

C00002/32

0: Off / ready

Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00002 | Device command

Data type: UNSIGNED_8

Index: 24573

d

= 5FFD

h

Advertising