Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

247

7

Technology applications

7.4

TA "Switch-off positioning"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.4.4.1

Terminals 0

Related topics:

Truth table for activating the pre-switch off

( 240)

Connection

Assignment

Connection

Assignment

DI1

FB

L_JogCtrlExtension_1

.bJogSpeed1

RFR

-

DI2

FB

L_JogCtrlExtension_1

.bJogSpeed2

AU/AI

LA_NCtrl.nMainSetValue_a

10 V ≡ 100 % reference speed (

C00011

)

DI3

LA_NCtrl.bFailReset

DI4

LA_NCtrl.bSetSpeedCcw

NO, COM

LA_NCtrl.bDriveFail

DI5

LA_NCtrl.bBrkRelease

DO1

LA_NCtrl.bDriveReady

X3/X4

NO

COM

AR

AU/AI

GND

RFR

DI1

DI2

DI3

DI4

DI5

DO1

24O

GND

Speed setpoint

Enable controller

Selection of fixed setpoint 1/3

Selection of fixed setpoint 2/3

Reset error message

Direction of rotation CCw

Manual release of the holding brake

DriveFail

DriveReady