Motor control (MCTRL)

5.9

Sensorless control for synchronous motors (SLPSM)

128

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

The motor model-based speed monitoring requires a rotating machine. Thus, the operational

performance of the sensorless control for synchronous motors is divided into two categories:

1. Open-loop controlled operation (|n

setpoint

| < n

C00996

)

• In the range of low speeds, the speed of a synchronous motor is not possible. Thus, only an

adjustable and constant current is injected that enables an acceleration.

2. Closed-loop controlled operation (|n

setpoint

| > n

C00996

)

• In this range, the rotor flux position and the speed are reconstructed via an observer. The

control is carried out field-oriented. Only the current is injected that is needed for the

required torque.

[5-5]

Operating ranges of the sensorless control for synchronous motors

The sensorless control for synchronous motors has similar advantages for the closed-loop

controlled operating range and the servo control (SC) for synchronous motors. Compared to

asynchronous motors, there are the following advantages:

• Higher power density of the motor
• Higher efficiency
• Limitation of the maximum torque in motor mode and generator mode in closed-loop

operating range

• Implementation of simple positioning

 Operation in motor mode (CW rotation),  Operation in generator mode (CCW rotation),

 Operation in motor mode (CCW rotation),  Operation in generator mode (CW rotation)

Field weakening

Closed-loop controlled operation

Open-loop controlled operation

Œ



Ž



Œ

0

1

2

3

M

n

Advertising