L_NSet_1

444

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Parameter

Identifier

Data type

Value/meaning

nNOut_a

INT

Speed setpoint output signal

• Scaling: 16384 ≡ 100 %

wState

WORD

Bit-coded status word

• Bits that are not listed are reserved for future extensions.

Bit 0 No blocking zone active
Bit 1 Blocking zone 1 active
Bit 2 Blocking zone 2 active
Bit 3 Blocking zone 3 active
Bit 4 Jog in blocking zone
Bit 5 MaxLimit active
Bit 6 MinLimit active

Parameter

Possible settings

Info

C00012

0.0

s

999.9 Acceleration time T

ir

for the main

setpoint

• Lenze setting: 2.0 s

C00013

0.0

s

999.9 Deceleration time T

if

for the main

setpoint

• Lenze setting: 2.0 s

C00039/1

-199.9

%

199.9 Fixed setpoint 1 (JOG setpoint 1)

• Lenze setting: 40.0 %

C00039/2

-199.9

%

199.9 Fixed setpoint 2 (JOG setpoint 2)

• Lenze setting: 60.0 %

C00039/3

-199.9

%

199.9 Fixed setpoint 3 (JOG setpoint 3)

• Lenze setting: 80.0 %

C00134

Activates ramp rounding with PT1

behaviour for the main setpoint

• The corresponding S-ramp time

must be set in

C00182

.

• Lenze setting: 0 (deactivated)

0 Off
1 PT1 behaviour

C00182

0.01

s

50.00 S-ramp time PT1

• Lenze setting: 20.00 s

C00632/1...3

0.0

%

199.9 Maximum limit values for the speed

blocking zones

• Selection of the maximum limit

values for the blocking zones in

which the speed must not be

constant.

• Lenze setting: 0.0 %

C00633/1...3

0.0

%

199.9 Minimum limit values for the speed

blocking zones

• Selection of the minimum limit

values for the blocking zones in

which the speed must not be

constant.

• Lenze setting: 0.0 %