Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

413

11

Parameter reference

11.2

Parameter list | C01092

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01092

C01100

C01101

Parameter | Name:

C01092 | LS_ParReadWrite_1: FailState

Data type: UNSIGNED_16

Index: 23483

d

= 5BBB

h

From version 04.00.00

Error status:

• 0 = no error

• 33803 | 0x840B = invalid data type (e.g. STRING)

• 33804 | 0x840C = limit violation

• 33806 | 0x840E = invalid code

• 33813 | 0x8415 = no element of the selection list

• 33815 | 0x8417 = writing of the parameter not permitted

• 33816 | 0x8418 = writing of the parameter only permitted if controller is inhibited

• 33829 | 0x8425 = invalid subcode

• 33865 | 0x8449 = no parameter with subcodes

Display range

(min. value | unit | max. value)

0

34000

Subcodes

Info

C01092/1

LS_ParReadWrite_1

: FailState

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01100 | L_Counter_1: Function

Data type: UNSIGNED_8

Index: 23475

d

= 5BB3

h

Selection of reset function
Selection list

0 Normal counting
1 Auto reset
2 Manual reset

Subcodes

Lenze setting

Info

C01100/1

0: Normal counting

L_Counter_1

: Function

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01101 | L_Counter_1: Comparison

Data type: UNSIGNED_8

Index: 23474

d

= 5BB2

h

Selection of comparison operation
Selection list

0 Greater than or equal to
1 Less than or equal to
2 equal to

Subcodes

Lenze setting

Info

C01101/1

0: Greater than or equal to

L_Counter_1

: Comparison

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1