C00134 | ramp rounding main setpoint, C00136 | communication control words, C00136/1 – Lenze 8400 motec User Manual

Page 354: C00134, 11 parameter reference

Advertising
background image

11

Parameter reference

11.2

Parameter list | C00134

354

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00134

C00136

Parameter | Name:

C00134 | Ramp rounding main setpoint

Data type: UNSIGNED_8

Index: 24441

d

= 5F79

h

The

L_NSet_1

FB: Configuration of the ramp rounding for the main setpoint

Selection list

(Lenze setting printed in bold)

Info

0 Off

Ramp rounding deactivated

1 PT1 behaviour

Ramp rounding with PT1 behaviour

• The corresponding S-ramp time must be set in

C00182

.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00136 | Communication control words

Data type: UNSIGNED_16

Index: 24439

d

= 5F77

h

Communication

Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 SwitchOn
Bit 1 IMP
Bit 2 SetQuickStop
Bit 3 EnableOperation
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 ResetFault
Bit 8 SetHalt
Bit 9 reserved_1

Bit 10 reserved_2
Bit 11 LenzeSpecific_1
Bit 12 LenzeSpecific_2
Bit 13 LenzeSpecific_3
Bit 14 SetFail
Bit 15 LenzeSpecific_4

Subcodes

Info

C00136/1

Network MCI/CAN control word

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Advertising