C02607 | holding brake: status, C02610 | mck: accel./decel. times, C02610/1 – Lenze 8400 motec User Manual

Page 425: C02607, Ymore, 11 parameter reference

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

425

11

Parameter reference

11.2

Parameter list | C02607

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02607

C02610

Parameter | Name:

C02607 | Holding brake: Status

Data type: UNSIGNED_16

Index: 21968

d

= 55D0

h

Switching status of the holding brake control

Holding brake control

Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Brake applied

Holding brake is completely applied

Bit 1 Brake released

Holding brake is completely released

Bit 2 Feedforward control active

Feedforward control for holding of the load via the motor

is active before the holding brake releases.

Bit 3 Closing active

The brake closing time (

C02589/1

) expires

Bit 4 Forced release active

In case of automatic operation of the holding brake

control, the brake is directly released via the MCK input

bMBrakeRelease = TRUE

Bit 5 Release active

The brake release time (

C02589/2

) expires

Bit 6 Setpoint synchronisation active

A speed setpoint at the MCK is approached along a

defined ramp after brake release

Bit 7 Brake control fault

Motor phase error detected before brake is released. For

configuration of monitoring see

C00597

.

Bit 8 Reserved
Bit 9 Reserved

Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C02610 | MCK: Accel./decel. times

Data type: UNSIGNED_32

Index: 21965

d

= 55CD

h

From version 02.00.00

Ramp times for speed setpoint synchronisation
Setting range

(min. value | unit | max. value)

0.0

s

999.9

Subcodes

Lenze setting

Info

C02610/1

2.0 s

Holding brake: ramp time synchr.

• Ramp time for the synchronisation process to

setpoint speed after the brake opening time has

elapsed

Holding brake control

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Advertising