V/f characteristic control - energy-saving (VFCplusEco)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.6.4.3

Optimising the cos/phi controller

With the Lenze setting, the cosϕ controller is set such that usually no adaptation is required for all

power ratings and application cases.

Behaviour

Remedy/recommendation

The cosϕ actual value (

C00979/1

) varies greatly.

Reduce gain Vp (

C00975

) and reset time Ti (

C00976

).

The cosϕ actual value (

C00979/1

) is permanently lower

than the cosϕ setpoint (

C00979/2

).

Increase gain Vp (

C00975

) and reset time Ti (

C00976

).