3 optimising the cos/phi controller, Optimising the cos/phi controller, 5motor control (mctrl) – Lenze 8400 motec User Manual
Page 113
Advertising
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
113
5
Motor control (MCTRL)
5.6
V/f characteristic control - energy-saving (VFCplusEco)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.6.4.3
Optimising the cos/phi controller
With the Lenze setting, the cosϕ controller is set such that usually no adaptation is required for all
power ratings and application cases.
Behaviour
Remedy/recommendation
The cosϕ actual value (
) varies greatly.
Reduce gain Vp (
) and reset time Ti (
The cosϕ actual value (
) is permanently lower
than the cosϕ setpoint (
Increase gain Vp (
) and reset time Ti (
).