C00425 | encoder scanning time, C00425/1, C00425 – Lenze 8400 motec User Manual

Page 373: 11 parameter reference

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

373

11

Parameter reference

11.2

Parameter list | C00425

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00425

Parameter | Name:

C00425 | Encoder scanning time

Data type: UNSIGNED_8

Index: 24150

d

= 5E56

h

From version 02.00.00

Encoder sample time for the digital input terminals when configured as frequency inputs

Using DI1 and DI2 as frequency inputs

Selection list

0 1 ms
1 2 ms
2 5 ms
3 10 ms
4 20 ms
5 50 ms
6 100 ms
7 200 ms
8 500 ms
9 1000 ms

Subcodes

Lenze setting

Info

C00425/1

3: 10 ms

Encoder sample time FreqIn12

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1