5motor control (mctrl) – Lenze 8400 motec User Manual

Page 168

Advertising
background image

5

Motor control (MCTRL)

5.12

Braking operation/brake energy management

168

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

How to set the "inverter motor brake" function for an oscillation-reduced operation:
For V/f characteristic open-loop control/closed-loop control (VFCplus):

• Set additive speed (

C00987

) to rated slip speed.

• Adapt the deceleration ramp so that the deceleration time is slightly below (10 ... 30 %)

the deceleration time that can be realised with the inverter motor brake.

How to set the "inverter motor brake" function for a maximum acceleration ramp:
For V/f characteristic open-loop control/closed-loop control (VFCplus):

• Set additive speed (

C00987

) to 1,5 ... 2,5-fold rated slip speed.

• Adapt the deceleration ramp so that the deceleration time is slightly below (10 ... 30 %)

the deceleration time that can be realised with the inverter motor brake.

For sensorless vector control (SLVC):

• Set additive speed (

C00987

) to 2 ... 4-fold rated slip speed.

• Adapt the deceleration ramp so that the deceleration time is slightly below (10 ... 30 %)

the deceleration time that can be realised with the inverter motor brake.

Advertising