Technology applications

7.2

TA "Actuating drive speed"

202

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.2.1

Basic signal flow

When you go to the Application parameters tab to the top dialog level Overview and click the Signal

flow button, you will get one dialog level down to the signal flow of the application (here displayed

with the preset control mode "Terminals 0"):

Configuration parameters for digital control signals:

 Motor potentiometer (

L_MPot_1

)

 Device control (

LS_DriveInterface

)

 Setpoint generator (

L_NSet_1

)

Motor control (MCTRL)

 Process controller (

L_PCTRL_1

)

"GeneralPurpose" functions

All input and output interfaces of the application are described in the chapter entitled

"

Interface description

".

( 206)

Parameter

Selection of signal source

(Lenze setting)

for control signal:

bMPotUp

(

C00701/8

)

0: Not connected

L_MPot_1

: Increase speed setpoint

bMPotDown

(

C00701/9

)

0: Not connected

L_MPot_1

: Decrease speed setpoint

bMPotInAct

(

C00701/10

)

0: Not connected

L_MPot_1

: Activate inactive function

bMPotEnable

(

C00701/11

)

0: Not connected

L_MPot_1

: Activate motor potentiometer function