291

9

Diagnostics & error management

9.6

Monitoring

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.6

Monitoring

The controller is provided with various monitoring functions which protect the drive against imper-

missible operating conditions.

• If a monitoring function responds,

• an entry will be made into the

Logbook

of the controller,

• the response (Trouble, Fault, etc.) set for this monitoring function will be triggered,
• the status of the internal device control changes according to the selected response, control-

ler inhibit is set, and the "DRIVE ERROR" LED on the top of the controller goes on:

Related topics:

LED status display

( 284)

Device state machine and device states

( 69)

Device overload monitoring (Ixt)

( 172)

Motor load monitoring (I2xt)

( 173)

Motor temperature monitoring (PTC)

( 176)

Brake resistor monitoring (I2xt)

( 177)

Mains phase failure monitoring

( 179)

Response

Entry in the

logbook

Display in

C00168

Disable volt-

age

Controller in-

hibit

Acknowl-

edgement re-

quired

LED red

"DRIVE ERROR"

None

OFF

Fault

Trouble

WarningLocked