5

Motor control (MCTRL)

5.14

Monitoring

172

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.14.1

Device overload monitoring (Ixt)

C00064/1...3

displays the device utilisation (ixt) in [%] in different time intervals:

• If the device utilisation reaches the warning threshold set in

C00123

(Lenze setting: 100 %):

• The error response set in

C00604

will be carried out (Lenze setting: "Warning").

• The "

OC5: Ixt overload

" error message will be entered into the Logbook.

• A setting of

C00604

= "0: No Reaction" deactivates the monitoring.

• If the device utilisation reaches the permanent shutdown limit 110 %:

• The error response "Fault" will be carried out.
• The "

OC9: Ixt overload shutdown limit

" error message will be entered into the logbook.

Parameter

Info

C00064/1

Device utilisation (Ixt)

• Maximum value of pulse utilisation (

C00064/2

)

and permanent utilisation (

C00064/3

).

C00064/2

Device utilisation (Ixt) 15s

• Pulse utilisation over the last 15 seconds (only for loads >160 %).

C00064/3

Device utilisation (Ixt) 3 min

• Permanent utilisation over the last 3 minutes.

Highlighted in grey = display parameter