12 function library – Lenze 8400 motec User Manual
Page 467
Advertising
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
467
12
Function library
12.7
L_DigitalDelay_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Function
1. A FALSE-TRUE edge at bIn starts the internal timing element for the ON delay.
2. After the defined ON delay, the input signal bIn is output at bOut.
3. A TRUE-FALSE edge at bIn starts the internal timing element for the OFF delay.
4. After the defined OFF delay, the input signal bIn is output at bOut.
ON delay
OFF delay
Internal timing element for ON delay (retriggerable)
Internal timing element for OFF delay (retriggerable)
TRUE
FALSE
bOut
t
TRUE
FALSE
bIn
t
t
0
t
1