Parameter list | C01083

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01083

C01084

C01085

C01086

Parameter | Name:

C01083 | LS_WriteParamList: FailState

Data type: UNSIGNED_16

Index: 23492

d

= 5BC4

h

Parameter change-over

: Error status:

• 0 = no error

• 33803 | 0x840B = invalid data type (e.g. STRING)

• 33804 | 0x840C = limit violation

• 33806 | 0x840E = invalid code

• 33813 | 0x8415 = no element of the selection list

• 33815 | 0x8417 = writing of the parameter not permitted

• 33816 | 0x8418 = writing of the parameter only permitted if controller is inhibited

• 33829 | 0x8425 = invalid subcode

• 33865 | 0x8449 = no parameter with subcodes

Display range

(min. value | unit | max. value)

0

34000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01084 | LS_WriteParamList: Error line

Data type: UNSIGNED_8

Index: 23491

d

= 5BC3

h

Parameter change-over

: Display of the number of list entry where the error occurred (in connection with the value

set selected via bSelectWriteValue_1 and bSelectWriteValue_2).
Display range

(min. value | unit | max. value)

0

16

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01085 | LS_WriteParamList: Index

Data type: INTEGER_32

Index: 23490

d

= 5BC2

h

Parameter change-over

: Parameter for entry 1 ... 16

Setting range

(min. value | unit | max. value)

0.000

16000.000

Subcodes

Lenze setting

Info

C01085/1

0.000

Parameter for entries 1 ... 16

• Format: <code number>.<subcode number>

• Examples: "12.000" = C00012; "26.001" = C00026/1

C01085/...
C01085/16

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01086 | LS_WriteParamList: WriteValue_1

Data type: INTEGER_32

Index: 23489

d

= 5BC1

h

Parameter change-over

: Parameter values - value set 1

Setting range

(min. value | unit | max. value)

-2147483647

2147483647

Subcodes

Lenze setting

Info

C01086/1

0

Parameter values - value set 1

• Parameter values for the parameters defined in

C01085

/1 ... 16.

C01086/...
C01086/16

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1