C00143 | selection of special functions, C00144 | switching frequency reduction (temp.), C00144 – Lenze 8400 motec User Manual

Page 357: Ted via, C00143, 11 parameter reference

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

357

11

Parameter reference

11.2

Parameter list | C00143

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00143

C00144

Parameter | Name:

C00143 | Selection of special functions

Data type: UNSIGNED_16

Index: 24432

d

= 5F70

h

From version 04.01.00

Setting range

(min. hex value | max. hex value)

Lenze setting

0x0000

0xFFFF 0x0000 (decimal: 0)

Value is bit-coded: (= bit set)

Info

Bit 0  Brightness of the green LED

Bit 1 | Bit 0: Brightness of the green LED

• 0 | 0 ≡ Maximum brightness

• 0 | 1 ≡ Reduced brightness - stage 1

• 1 | 0 ≡ Reduced brightness - stage 2

• 1 | 1 ≡ Minimum brightness

Use this function if the green light is too bright or

disturbing for your application.

• The green LED cannot be switched off completely in

order that the supply of the device with 400 V

remains visibly displayed from the outside.

• The setting only affects the green LED, not the red LED

(fault indication).

Bit 1  Brightness of the green LED
Bit 2  Reserved
Bit 3  Reserved
Bit 4  Reserved
Bit 5  Reserved
Bit 6  Reserved
Bit 7  Reserved
Bit 8  No IMP before DCB

From version 05.00.00

If this bit is set and the auto DCB threshold is ≤ 5 Hz, the

DC-injection braking is activated immediately if the

value falls below the threshold (without waiting time).

Automatic DC-injection braking (auto DCB)

Bit 9  Reserved

Bit 10  Reserved
Bit 11  Reserved
Bit 12  Reserved
Bit 13  Reserved
Bit 14  Reserved
Bit 15  Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00144 | Switching frequency reduction (temp.)

Data type: UNSIGNED_8

Index: 24431

d

= 5F6F

h

Activation of the automatic switching frequency reduction if the temperature is too high
Selection list

(Lenze setting printed in bold)

Info

0 Off

Automatic switching frequency reduction deactivated

1 On

Automatic switching frequency reduction activated

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising