C01353 | acdrive: setpoint scaling, C01354 | ls_convert, C01354/2 – Lenze 8400 motec User Manual

Page 417: C01353/1, C01353/2, 11 parameter reference

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

417

11

Parameter reference

11.2

Parameter list | C01353

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01353

C01354

Parameter | Name:

C01353 | ACDrive: Setpoint scaling

Data type: INTEGER_8

Index: 23222

d

= 5AB6

h

From version 05.00.00

Application "Speed actuating drive (AC Drive Profile)": Scaling of the speed and torque values

Setting range

(min. value | unit | max. value)

-128

127

Subcodes

Lenze setting

Info

C01353/1

0

ACDrive: Speed scaling

C01353/2

0

ACDrive: Torque scaling

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01354 | LS_Convert

Data type: UNSIGNED_8

Index: 23221

d

= 5AB5

h

From version 05.00.00

Selection list

0 1 ==> 1 ==> 1
1 1 Hz ==> % (C11) ==> 1 Hz
2 0.1 Hz ==> % (C11) ==> 0.1 Hz
3 0.01 Hz ==> % (C11) ==> 0.01 Hz
4 0.001 Hz ==> % (C11) ==> 0.001 Hz
5 1 Rpm ==> % (C11) ==> 1 Rpm
6 0.1 Rpm ==> % (C11) ==> 0.1 Rpm
7 0.01 Rpm ==> % (C11) ==> 0.01 Rpm
8 0.001 Rpm ==> % (C11) ==> 0.001

Rpm

9 1 A ==> % (C22) ==> 1 A

10 0.1 A ==> % (C22) ==> 0.1 A
11 0.01 A ==> % (C22) ==> 0.01 A
12 0.001 A ==> % (C22) ==> 0.001 A
13 1 Nm ==> % (C57) ==> 1 Nm
14 0.1 Nm ==> % (C57) ==> 0.1 Nm
15 0.01 Nm ==> % (C57) ==> 0.01 Nm
16 0.001 Nm ==> % (C57) ==> 0.001 Nm
17 ACDP ==> CAN ==> ACDP
18 x C471_1 / C471_2
19 Act position 32bit ==> 16Bit

Subcodes

Lenze setting

Info

C01354/1

0: 1 ==> 1 ==> 1

LS_Convert_1

: Function

C01354/2

0: 1 ==> 1 ==> 1

LS_Convert_2

: Function

C01354/3

0: 1 ==> 1 ==> 1

LS_Convert_3

: Function

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1