12

Function library

12.2

L_NSet_1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.2.1

Main setpoint path

• The signals in the main setpoint path are limited to a value range of ±32767.
• The signal at nNSet_a is first led via the JOG selection function.
• A selected JOG value switches the nNSet_a input inactive. Then, the subsequent signal

conditioning operates with the JOG value.

12.2.2

JOG setpoints

In addition to the direct main setpoint selection via the nNSet_a input, so-called JOG setpoints can

be preset in

C00039/1...3

.

• The JOG setpoints are binary-coded and can be called using the bJog1 and bJog8 selection

inputs:

• The number of selection inputs to be assigned depends on the number of JOG setpoints

required.

12.2.3

Setpoint inversion

The output signal of the JOG function is led via an inverter.
The sign of the setpoint changes if bNSetInv is set to TRUE.

C00634

Status (bit-coded)

• Bits that are not listed are

reserved for future extensions.

Bit 0 No blocking zone active
Bit 1 Blocking zone 1 active
Bit 2 Blocking zone 2 active
Bit 3 Blocking zone 3 active
Bit 4 Jog in blocking zone
Bit 5 MaxLimit active
Bit 6 MinLimit active

Parameter

Possible settings

Info

Selection inputs

Used main setpoint

bJog2

bJog1

FALSE

FALSE

nNset_a

FALSE

TRUE

C00039/1

TRUE

FALSE

C00039/2

TRUE

TRUE

C00039/3