C00581 | resp. to ls_seterror_x, C00585 | resp. to motor overtemp. ptc, C00585 – Lenze 8400 motec User Manual

Page 384: Is activated, Fault"), mo, C00582, C00581/1, C00581/2, 11 parameter reference

Advertising
background image

11

Parameter reference

11.2

Parameter list | C00581

384

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00581

C00582

C00585

Parameter | Name:

C00581 | Resp. to LS_SetError_x

Data type: UNSIGNED_8

Index: 23994

d

= 5DBA

h

Selection of the error responses for application error messages

• An application error message is tripped by a FALSE-TRUE edge at the binary inputs bSetError1...2.

Selection list

0 No Reaction
1 Fault
2 Trouble
4 WarningLocked

Subcodes

Lenze setting

Info

C00581/1

1: Fault

LS_SetError_1

: Resp. to bSetError1

C00581/2

1: Fault

LS_SetError_1

: Resp. to bSetError2

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00582 | Resp. to heatsink temp. > shutdown temp. -5°C

Data type: UNSIGNED_8

Index: 23993

d

= 5DB9

h

Response if the heatsink temperature has reached the switch-off temperature threshold.
Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
4 WarningLocked

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00585 | Resp. to motor overtemp. PTC

Data type: UNSIGNED_8

Index: 23990

d

= 5DB6

h

Response to motor overtemperature

• The motor temperature is measured by means of a PTC thermistor detector.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
4 WarningLocked

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1