9

Diagnostics & error management

9.8

Error messages of the operating system

310

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Smr3: Module timeout - one or more of PDOs timeout [xx.0127.00005]

Smr4: SDO access failure [xx.0127.00006]

CE0F: MCI control word [xx.0127.00015]

CE4: CAN bus off [xx.0131.00000]

CA06: CAN CRC error [xx.0131.00002]

Response (Lenze setting printed in bold)

No Reaction  Fault  Trouble  WarningLocked

Cause

Remedy

Communication Unit: A timeout has occurred for one or

several PDOs

• Increase timeout in

C01503/1

.

• Mains switching or restart of the controller, respec-

tively.

• Check correct identification of the Communication

Unit in

C00203/3

.

• Replace Communication Unit.

• Please contact Lenze if the problem occurs again.

Response (Lenze setting printed in bold)

No Reaction  Fault  Trouble  WarningLocked

Cause

Remedy

An error has occurred during SDO access

• Mains switching or restart of the controller, respec-

tively.

• Please contact Lenze if the problem occurs again.

Response (Lenze setting printed in bold)

Setting:

C00594/2

( Adjustable response)

No Reaction  Fault  Trouble  WarningLocked

Cause

Remedy

Bit 14 ("SetFail") of the wMciCtrl control word of the

LS_DriveInterface

system block has been set.

Trace back signal source on the bus (e.g. PROFIBUS) that

sets bit 14 ("SetFail").

Response (Lenze setting printed in bold)

Setting:

C00592/2

( Adjustable response)

No Reaction  Fault  Trouble  WarningLocked

Cause

Remedy

CAN interface: "Bus-Off" state

• Received too many faulty telegrams.

• Damaged cable (e.g. loose contact).

• Two nodes with the same ID.

• Check wiring and bus terminating resistor.

• Set identical baud rate for each bus node.

• Assign different IDs to nodes.

• Eliminate electrical interference (e.g. EMC).

Response (Lenze setting printed in bold)

Setting:

C00592/1

( Adjustable response)

No Reaction  Fault  Trouble  WarningLocked

Cause

Remedy

CAN interface: a faulty CAN telegram has been detected.

• Check wiring and bus terminating resistor.

• Eliminate electrical interference (e.g. EMC).