C00937

C00938

C00939

C00965

Parameter | Name:

C00937 | Field-oriented motor currents

Data type: INTEGER_16

Index: 23638

d

= 5C56

h

From version 04.00.00

Field weakening for synchronous motors

Display range

(min. value | unit | max. value)

0.00

A

320.00

Subcodes

Info

C00937/1

Field-producing current

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00938 | PSM: Maximum motor current field weakening

Data type: UNSIGNED_16

Index: 23637

d

= 5C55

h

From version 04.00.00

Field weakening for synchronous motors

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

500.00 30.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00939 | Ultimate motor current

Data type: UNSIGNED_16

Index: 23636

d

= 5C54

h

From version 03.00.00

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

A

3000.0 3000.0 A

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00965 | Max. motor speed

Data type: UNSIGNED_16

Index: 23610

d

= 5C3A

h

From version 04.00.00

When the drive reaches the motor speed set here:

• The "Fault" error response takes place, i.e. the motor is shut down immediately.

• The error message "

oS2: Max. motor speed reached

" is entered into the logbook.

Setting range

(min. value | unit | max. value)

Lenze setting

50

rpm

9999 9999 rpm

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1