3

Commissioning

3.6

Commissioning of the "Switch-off positioning" technology application

42

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.6

Commissioning of the "Switch-off positioning" technology application

[3-2]

Block diagram for wiring of the commissioning example for the "Switch-off positioning" technology application

Note!

Take all the necessary safety precautions before you carry out the following

commissioning steps and switch the device on!

Safety instructions with regard to commissioning

( 31)

System constellation

RFR

Controller enable

DI1

Initiator connection for stop function 1

DI2

Initiator connection for stop function 2

DI3

Quick stop for CW rotation / selection of switch-off position 1

DI4

Quick stop for CCW rotation / selection of switch-off position 2

DIAG

Diagnostic interface for connecting the USB diagnostic adapter

8400 motec

X61

X6

DIAG

U V W

DO1 24O GND

NO COM AR

AU GND

X3/X4

RFR DI1 DI2 DI3 DI4 DI5 DO1 24O GND

NO COM

t [s]

0
1

QSP

Cw

Ccw

-

DI1

DI2

DI1

DI2

v [m/s]

C00039/3

C00012

C00012

C00013

C00039/3

C00013

Cw
Ccw

Cw

Ccw

M

3~

i

0
1

0
0

1

1

Advertising