12 function library – Lenze 8400 motec User Manual

Page 453

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

453

12

Function library

12.3

L_PCTRL_1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00242

Operating mode

• Lenze setting: "0: Off"

0 Off

The input setpoint nNSet_a is output

without any changes at the output

nOut_a.

1 nNSet + nNSet_PID

nNSet_a and nAct_a are used as PID

input values. The arriving nNSet_a is

additively linked to the value output

by the PID element.

2 nSet_PID

nSet_a and nAct_a are used as PID

input values. The input nNSet_a is

not considered.

3 nNSet_PID

nNSet_a and nAct_a are used as PID

input values. The input nSet_a is not

considered.

4 nNSet + nSet_PID

(from version 04.00.00)

nSet_a and nAct_a are used as PID

input values. The arriving nNSet_a

setpoint is additively linked to the

value output by the PID element.

5 nNSet || nSet_PID

(from version 04.00.00)

nSet_a and nAct_a are used as PID

input values. The setpoint nNSet_a is

output at the output nOut_a . The

PID output value is output at the

output nPIDOut_a.

C00243

0.0

s

999.9 Influence acceleration time

• Acceleration time T

ir

for the

influencing factor.

• Lenze setting: 5.0 s

C00244

0.0

s

999.9 Influence deceleration time

• Deceleration time T

if

for the

influencing factor.

• Lenze setting: 5.0 s

C00245

-199.9

%

+199.9 Display of PID output value

nPIDOut_a

C00246

(from version 04.00.00)

-199.99

%

+199.99 Display of the internal PID input

value nAct_a

Parameter

Possible settings

Info