6i/o terminals – Lenze 8400 motec User Manual

Page 187

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

187

6

I/O terminals

6.1

Digital terminals

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Function assignment 3: DI1=FreqIn / DI2=direction
This setting in

C00115/1

serves to connect a single-track encoder to the terminals DI1/DI2. Here, the

rotational speed is evaluated via terminal DI1 and the direction of rotation of the encoder (LOW

level ≡ CW rotation) is evaluated via terminal DI2.

Short overview of the parameters for the frequency inputs:

Parameter

Info

Lenze setting

Value Unit

C00011

Appl.: Reference speed

1500 rpm

Frequency input DI1/DI2

C00115/1

Fkt. DI 1/2 10kHz

0: DI1=In1 / DI2=In2

C00420/1

Encoder increments at FreqIn12

128 Incr./rev.

C02842/1

FreqIn12: Offset

0.00 %

C02843/1

FreqIn12: Gain

100.00 %

C00443/1

DIx: Terminal level

-

C00445/1

FreqIn12_nOut_v

- Incr/ms

C00446/1

FreqIn12_nOut_a

- %

Highlighted in grey = display parameter

Q)UHT,QBD







2IIVHW

*DLQ

&

&







Q)UHT,QBY

&

&

',

0&75/B6SHHGIHHGEDFN

',

N+]




&%LW

&%LW

Advertising