_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Input and output signals of the holding brake control:

Short overview of parameters for holding brake control:

Input

Data type

Configuration parameters

Information/possible settings

bBrkRelease

BOOL

C00701/19

Manual release of the brake in connection with the selected operating mode.

• In the Lenze setting, this input is connected to the digital input DI5.

FALSE Do not release the brake manually.

TRUE Release brake manually (forced release).

Note!

The brake can also be released if the controller is inhibited!

• During automatic operation, the internal brake logic is

deactivated and the brake is released (supervisor operation). If a

controller inhibit has been set by the brake control, it will be

deactivated.

• In semi-automatic operation, the brake is released including

feedforward control.

Output

Data type

Value/meaning

bBrkReleaseOut

BOOL

Trigger signal for the motec-internal power output (terminals BR1 and BR2) for

triggering the brake.

• Use bit 0 in

C02582

to activate inverted triggering of the power output.

Functional settings

FALSE Apply brake.

TRUE Release brake.

bBrkReleased

BOOL

"Brake released" status signal considering the brake release time

• When the holding brake is triggered to close, bBrkReleased is immediately set to

FALSE even if the brake closing time has not yet elapsed!

TRUE Brake released (after the brake release time has expired).

Parameter

Info

Lenze setting

Value Unit

C00701/19

Signal source for bBrkRelease

15: DigIn_bIn5

C02580

Holding brake: Operating mode

0: Brake control off

C02581/1

Holding brake: Switching threshold

5.00 %

C02581/2

Holding brake: Hyst. release

1.00 %

C02581/3

Holding brake: Hyst. close

1.00 %

C02582

Holding brake: Setting

0

C02589/1

Holding brake: Closing time

100 ms

C02589/2

Holding brake: Release time

100 ms

C02593/1

Holding brake: Actual value monitoring

0.000 ms

C02593/2

Holding brake: Application delay

0.000 ms

C02610/1

MCK: Holding brake ramp time synchr.

2.0 s

C02607

Holding brake: Status

-

C00158

Cause of controller inhibit
 Bit 12: Automatic brake operation

-

C00833/24

MCK: bBrkRelease

-

Highlighted in grey = display parameter