2 parameter list, C00002 | device command, C00002 – Lenze 8400 motec User Manual

Page 331: C00002/x, C00003, By writing to, C00002/1, C00002/16, A dynamic stat, C00002/2

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

331

11

Parameter reference

11.2

Parameter list

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.2

Parameter list

This chapter lists all parameters of the operating system in numerically ascending order.

C00002

Note!

The parameter descriptions are based on the software version V05.00.00.

Parameter | Name:

C00002 | Device command

Data type: UNSIGNED_8

Index: 24573

d

= 5FFD

h

Note:

• Before switching off the supply voltage after carrying out a device command, check whether the device

command has been carried out successfully via the status display under

C00003

!

• Before activating device commands by a master control, wait for the "Ready" signal of the controller.

• The device will reject a write process to C00002/x if the value is >1 and issue an error message.

Drive control (DCTRL)

:

Device commands

Selection list

0 Off / ready
1 On / start
2 Work in progress
4 Action cancelled
5 No access
6 No access controller inhibit

Subcodes

Lenze setting

Info

C00002/1

0: Off / ready

Load Lenze setting

• All parameters are reset to the Lenze setting.

• Only possible when the controller is inhibited.

C00002/2

0: Off / ready

Load parameter set 1

• Load parameter set 1 from the memory module.

C00002/3

0: Off / ready

Reserved

C00002/4

0: Off / ready

Reserved

C00002/5

0: Off / ready

Reserved

C00002/6

0: Off / ready

Reserved

C00002/7

0: Off / ready

Save parameter set 1

• Saving parameter set 1 in the memory module safe

against mains failure.

C00002/8

0: Off / ready

Reserved

C00002/9

0: Off / ready

Reserved

C00002/10

0: Off / ready

Reserved

C00002/11

0: Off / ready

Save all parameter sets

• All parameter sets are saved to the memory module

safe against mains failure.

C00002/12

0: Off / ready

Importing EPM data

• Setting "1: On / start" activates the automatic import

of parameters of the memory module after the error

message "PS04".

C00002/13

0: Off / ready

Reserved

Advertising