1 functional principle, Functional principle, 7technology applications – Lenze 8400 motec User Manual

Page 240

Advertising
background image

7

Technology applications

7.4

TA "Switch-off positioning"

240

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.4.1

Functional principle

The switch-off positioning is based on the

TA "Actuating drive speed"

with the following functional

differences:

• The motor parameter function (FB

L_MPot_1

) and the process controller (FB

L_PCTRL_1

) are not

relevant for the switch-off positioning, thus these functions are switched off in the Lenze

setting. The speed setpoint is passed through 1:1 by these FBs.

• The logic of the switch-off positioning is contained in the upstream FB

L_JogCtrlExtension_1

.

• Depending on the selected control mode (

C00007

), this FB receives its control signals via

digital inputs and/or via network.

• A corresponding linking causes the FB outputs to trigger the setpoint generator

(FB

L_NSet_1

):

[7-1]

Functional principle

Truth table for activating the pre-switch off
The inputs bInputSel1 and bInputSel2 serve to select the pre-switch off according to the following

truth table:

bRFG_0

bJogSpeed2

bJogSpeed1

C701/6

C701/7

C701/12

L_JogCtrlExtension_1

bInputSel1

bInputSel2

bRfgIn

bJog1In

bRfgOut

bJog1Out
bJog2Out

bJog2In

bStop1

bSlowDown1

bStop2

bSlowDown2

bStop3

bSlowDown3

DMUX

3

0

1

2

3

0

CTRL

206
207

205

Entry in
select list:

bRfg0
bNSetInv

nNSet_a

bJog2

bJog1

nNOut_a

LA_NCtrl

L_NSet_1

C761/1

C761/2

C761/9

C761/10

C761/11

C761/3

C761/4

C761/5

C761/6

C761/7

C761/8

Edge detect.:

C488/1

C488/2

C488/3

C488/4

C488/5

C488/6

Digit

al
input

s

/

Network

signals

nMainSetValue_a

C700/1

Inputs

Function

Response in the setpoint generator

(FB

L_NSet_1

)

bInputSel1

bInputSel2

FALSE

FALSE

Pre-switch off inactive

No response

• The input signals bRfgIn, bJog1In

and bJog2In are passed through

1:1 to the upstream FB

L_NSet_1

.

TRUE

FALSE

The bSlowDown1 and bStop1 inputs are

evaluated.

Pre-switch off can be activated

• See the following

Truth table -

switch-off positioning

.

FALSE

TRUE

The bSlowDown2 and bStop2 inputs are

evaluated.

TRUE

TRUE

The bSlowDown3 and bStop3 inputs are

evaluated.

Advertising