195

6

I/O terminals

6.3

User-defined terminal assignment

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Configuration parameters for the digital output terminals
The subcodes of

C00621

can be used to change the preconfigured terminal assignment of the dig-

ital terminals:

Other subcodes (not shown here) allow the configuration of input signals of different system blocks

and port blocks.

Configuration parameters for the inputs of the application
The following parameters can be used to change the preconfigured assignment of the application

inputs:

Parameter

Info

Lenze setting

Value Unit

C00621/1

LS_DigitalOutput:bRelay

1001: LA_nCtrl_bDriveFail

C00621/2

LS_DigitalOutput:bOut1

1000: LA_nCtrl_bDriveReady

Parameter

Info

Lenze setting

C00700/1

LA_NCtrl

: nMainSetValue_a

10: AIn1_Out

C00700/2

LA_NCtrl

: nTorqueMotLim_a

22: nPar3_a

C00700/3

LA_NCtrl

: nTorqueGenLim_a

22: nPar3_a

C00700/4

Key-operated switch: Max. speed

15: Local potentiometer P1

C00700/5

LA_NCtrl

:Network(MCI/CAN)_wDriveControl

6: C_wDriveCtrl

C00700/6

LA_NCtrl

: nPIDVpAdapt_a

1: C_nPos100_a(100.0%)

C00700/7

LA_NCtrl

: nPIDActValue_a

0: Not connected

C00700/8

LA_NCtrl

: nPIDInfluence_a

1: C_nPos100_a(100.0%)

C00700/9

LA_NCtrl

: nPIDSetValue_a

0: Not connected

C00700/10

Reserved

0: Not connected

C00700/11

L_Counter_1

: wLdVal

0: Not connected

C00700/12

L_Counter_1

: wCmpVal

0: Not connected

C00700/13

L_Compare_1

: nIn1_a

0: Not connected

C00700/14

L_Compare_1

: nIn2_a

0: Not connected

C00700/15

LS_ParReadWrite_1

: wParIndex

0: Not connected

C00700/16

LS_ParReadWrite_1

: wParSubindex

0: Not connected

C00700/17

LS_ParReadWrite_1

: wInHWord

0: Not connected

C00700/18

LS_ParReadWrite_1

: wInLWord

0: Not connected

C00701/1

LA_NCtrl

: bCInh

0: Not connected

C00701/2

LA_NCtrl

: bFailReset

10: DigIn_CInh

C00701/3

LA_NCtrl

: bSetQuickstop

0: Not connected

C00701/4

LA_NCtrl

: bSetDCBrake

13: DigIn_bIn3

C00701/5

LA_NCtrl

: bSetSpeedCcw

14: DigIn_bIn4

C00701/6

LA_NCtrl

: bJogSpeed1

11: DigIn_bIn1

C00701/7

LA_NCtrl

: bJogSpeed2

12: DigIn_bIn2

C00701/8

LA_NCtrl

: bMPotUp

0: Not connected

C00701/9

LA_NCtrl

: bMPotDown

0: Not connected

C00701/10

LA_NCtrl

: bMPotInAct

0: Not connected

C00701/11

LA_NCtrl

: bMPotEnable

0: Not connected

C00701/12

LA_NCtrl

: bRFG_0

0: Not connected

C00701/13

LA_NCtrl

: bSetError1

0: Not connected

Advertising