background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

61

4

Device control (DCTRL)

4.1

Device commands (C00002/x)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Short overview of device commands

Activate device command
When an online connection has been established, simply use the »Engineer« to activate a device

command by selecting the corresponding option from the Parameters tab in

C00002/x

("0: off" or

"1: On / start").

• Alternatively, the device command can also be activated via e.g. keypad or through a master

control by writing to

C00002/x

.

• Some of the frequently used device commands (such as "Save parameter set") can also be exe-

cuted via the Toolbar icons of the »Engineer« when an online connection has been established:

C00002

Subcode:

Device command

Controller inhibit re-

quired

Status information

1

Load Lenze setting

dynamic

2

Load parameter set 1

dynamic

7 Save parameter set 1

Save parameter settings

dynamic

11 Save all parameter sets

Save parameter settings

dynamic

12

Importing EPM data

static

16

Enable/Inhibit controller

static

17

Activate/deactivate quick stop

static

19

Reset error

static

21

Delete logbook

static

23

Motor parameter identification

dynamic

26

CAN reset node

static

27

Device search function

(from version 04.00.00)

static

* Subcodes which are not listed are reserved for future extensions.

Icon

Function
Enable controller

Inhibit controller

Save parameter set (for 8400: Save all parameter sets)

Device search function

(from version 04.00.00)

Note!

Device commands that can be executed via the Toolbar of the »Engineer« always affect

the element currently selected in the Project view including all subelements!

• If no controller but e.g. a system module is selected in the Project view instead, the cor-

responding device command will be activated in all lower-level controllers that have

an online connection to the »Engineer«.

Before the desired action is carried out, a confirmation prompt appears first, asking

whether the action is really to be carried out.