C00701 | la_nctrl: digital connection list, C00701, C00701/2 – Lenze 8400 motec User Manual

Page 394: C00701/4, C00701/x, C00701/1, C00701/3, C00701/5, C00701/6, C00701/7

Advertising
background image

11

Parameter reference

11.2

Parameter list | C00701

394

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00701

Parameter | Name:

C00701 | LA_NCtrl: Digital connection list

Data type: UNSIGNED_16

Index: 23874

d

= 5D42

h

Selection list
See

selection list - digital signals

Subcodes

Lenze setting

Info

C00701/1

0: Not connected

LA_NCtrl

: bCInh

C00701/2

10: LS_DigitalInput: bCInh

LA_NCtrl

: bFailReset

C00701/3

0: Not connected

LA_NCtrl

: bSetQuickstop

C00701/4

13: LS_DigitalInput: bIn3

LA_NCtrl

: bSetDCBrake

C00701/5

14: LS_DigitalInput: bIn4

LA_NCtrl

: bSetSpeedCcw

C00701/6

11: LS_DigitalInput: bIn1

LA_NCtrl

: bJogSpeed1

C00701/7

12: LS_DigitalInput: bIn2

LA_NCtrl

: bJogSpeed2

C00701/8

0: Not connected

LA_NCtrl

: bMPotUp

C00701/9

0: Not connected

LA_NCtrl

: bMPotDown

C00701/10

0: Not connected

LA_NCtrl

: bMPotInAct

C00701/11

0: Not connected

LA_NCtrl

: bMPotEnable

C00701/12

0: Not connected

LA_NCtrl

: bRFG_0

C00701/13

0: Not connected

LA_NCtrl

: bSetError1

C00701/14

0: Not connected

LA_NCtrl

: bSetError2

C00701/15

1: LS_ParFix: bTrue

LA_NCtrl

: bPIDInfluenceRamp

C00701/16

0: Not connected

LA_NCtrl

: bPIDIOff

C00701/17

1: LS_ParFix: bTrue

LA_NCtrl

: bRLQCw

C00701/18

0: Not connected

LA_NCtrl

: bRLQCcw

C00701/19

15: LS_DigitalInput: bIn5

LA_NCtrl

: bBrkRelease

C00701/20

0: Not connected

L_Counter_1

: bClkUp

C00701/21

0: Not connected

L_Counter_1

: bClkDown

C00701/22

0: Not connected

L_Counter_1

: bLoad

C00701/23

0: Not connected

L_DigitalDelay_1

: bIn

C00701/24

0: Not connected

L_DigitalDelay_2

: bIn

C00701/25

0: Not connected

LS_WriteParamList

: bExecute

C00701/26

0: Not connected

LS_WriteParamList

: bSelectWriteValue_1

C00701/27

0: Not connected

L_FreqIn12: bEncCntReset

C00701/28

0: Not connected

L_DigitalLogic_1

: bIn1

C00701/29

0: Not connected

L_DigitalLogic_1

: bIn2

C00701/30

0: Not connected

L_DigitalLogic_2

: bIn1

C00701/31

0: Not connected

L_DigitalLogic_2

: bIn2

C00701/32

0: Not connected

LS_ParReadWrite_1

: bExecute

C00701/33

0: Not connected

LS_ParReadWrite_1

: bReadWrite

C00701/34

0: Not connected

LA_NCtrl

: bPIDInAct

C00701/35

0: Not connected

LA_NCtrl

: bPIDOff

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1