C00446 | freqinxx_nout_a, C00461 | remote: acceleration/deceleration time, C00463 | keypad – Lenze 8400 motec User Manual

Page 376: C00461/1, C00460, C00446/1, 11 parameter reference

Advertising
background image

11

Parameter reference

11.2

Parameter list | C00446

376

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00446

C00460

C00461

C00462

C00463

Parameter | Name:

C00446 | FreqInxx_nOut_a

Data type: INTEGER_16

Index: 24129

d

= 5E41

h

From version 02.00.00

Display of the frequency input signals which are fed into the application.

Using DI1 and DI2 as frequency inputs

Display range

(min. value | unit | max. value)

-199.9

%

199.9

Subcodes

Info

C00446/1

FreqIn12_nOut_a

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00460 | Remote: Local keyswitch

Data type: UNSIGNED_8

Index: 24115

d

= 5E33

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00461 | Remote: Acceleration/deceleration time

Data type: UNSIGNED_32

Index: 24114

d

= 5E32

h

From version 04.00.00

Acceleration/deceleration time for

PC manual control

and

Control via field package

("key-operated switch

operation")
Setting range

(min. value | unit | max. value)

0.0

s

999.9

Subcodes

Lenze setting

Info

C00461/1

2.0 s

Remote: Acceleration/deceleration time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C00462 | Keypad/PC: Setpoint control

Data type: UNSIGNED_16

Index: 24113

d

= 5E31

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00463 | Keypad:

Data type: INTEGER_32

Index: 24112

d

= 5E30

h

Setting range

(min. value | unit | max. value)

0.000

16000.000

Subcodes

Lenze setting

Info

C00463/1

729.001

Keypad: Parameter for speed setpoint

C00463/2

56.002

Keypad: Parameter for display bar

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000