1 terminals 0, 2 terminals 2, Terminals 0 – Lenze 8400 motec User Manual

Page 215: Terminals 2, 7technology applications

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

215

7

Technology applications

7.2

TA "Actuating drive speed"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.2.3.1

Terminals 0

7.2.3.2

Terminals 2

Connection

Assignment

Connection

Assignment

DI1

LA_NCtrl.bJogSpeed1

RFR

LA_NCtrl.bFailReset

DI2

LA_NCtrl.bJogSpeed2

AU/AI

LA_NCtrl.nMainSetValue_a

10 V ≡ 100 % reference speed (

C00011

)

DI3

LA_NCtrl.bSetDCBrake

DI4

LA_NCtrl.bSetSpeedCcw

NO, COM

LA_NCtrl.bDriveFail

DI5

LA_NCtrl.bBrkRelease

DO1

LA_NCtrl.bDriveReady

X3/X4

NO

COM

AR

AU/AI

GND

RFR

DI1

DI2

DI3

DI4

DI5

DO1

24O

GND

Speed setpoint

Enable controller / reset error message

Selection of fixed setpoint 1/3

Selection of fixed setpoint 2/3

Manual DC-injection braking (DCB)

Direction of rotation CCw

Manual release of the holding brake

DriveFail

DriveReady

Connection

Assignment

Connection

Assignment

DI1

LA_NCtrl.bJogSpeed1

RFR

LA_NCtrl.bFailReset

DI2

LA_NCtrl.bJogSpeed2

AU/AI

LA_NCtrl.nMainSetValue_a

10 V ≡ 100 % reference speed (

C00011

)

DI3

LA_NCtrl.bSetQuickstop

DI4

LA_NCtrl.bSetSpeedCcw

NO, COM

LA_NCtrl.bDriveFail

DI5

LA_NCtrl.bBrkRelease

DO1

LA_NCtrl.bDriveReady

NO

COM

AR

AU/AI

GND

RFR

DI1

DI2

DI3

DI4

DI5

DO1

24O

GND

X3/X4

Speed setpoint

Enable controller / reset error message

Selection of fixed setpoint 1/3

Selection of fixed setpoint 2/3

Quick stop

Direction of rotation CCw

Manual release of the holding brake

DriveFail

DriveReady

Advertising