C00604 | resp. to device overload (ixt), C00606 | resp. to motor overload (i·xt), C00607 | resp. to max. speed reached – Lenze 8400 motec User Manual
Page 387: C00620 | 16-bit system connection, C00604, C00606, C00620, C620/5, C620/6, C620/7
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
387
11
Parameter reference
11.2
Parameter list | C00604
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00604
C00606
C00607
C00620
Parameter | Name:
C00604 | Resp. to device overload (Ixt)
Data type: UNSIGNED_8
Index: 23971
d
= 5DA3
h
Response if the adjustable device utilisation threshold (
) is reached.
• The current device utilisation is displayed in
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
4 WarningLocked
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00606 | Resp. to motor overload (I²xt)
Data type: UNSIGNED_8
Index: 23969
d
= 5DA1
h
Response when the motor load displayed in
reaches the value "100.00 %".
Motor overload monitoring (I2xt)
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
4 WarningLocked
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00607 | Resp. to max. speed reached
Data type: UNSIGNED_8
Index: 23968
d
= 5DA0
h
From version 02.00.00
Response when the maximum input frequency has been reached via the digital inputs.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
4 WarningLocked
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00620 | 16-bit system connection
Data type: UNSIGNED_16
Index: 23955
d
= 5D93
h
Connection parameters: 16-bit inputs
• Selection of the 16 bit output signals to be connected to the 16 bit input signals
• The selection list contains all 16 bit output signals which can be assigned to the 16 bit inputs displayed by the
subcodes.
Selection list
See
selection list - analog signals
Subcodes
Lenze setting
Info
C00620/1
0: Not connected
Reserved
C00620/2
0: Not connected
Reserved
C00620/3
0: Not connected
Reserved
C00620/4
0: Not connected
Reserved