Basic functions
8.2
Holding brake control
280
Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
[8-7]
Close holding brake in automatic mode with actual value monitoring time (
C02593/1
> 0 s)
Feedforward control
: Switching threshold
: Hysteresis for release
: Hysteresis for application
: Application delay
: Actual value monitoring time
: Application time
bBrkReleaseOut
0
0
bBrkReleased
CINH
t
t
t
t
nSpeedSetValue_a_
0
nMotorSpeedAct_a
nSpeedSetValue_a