3 process when brake is closed, Process when brake is closed, Process when – Lenze 8400 motec User Manual

Page 279: Brake is closed, 8basic functions

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

279

8

Basic functions

8.2

Holding brake control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.2.3

Process when brake is closed

1. The motor is decelerated when the setpoint is reduced by the user (e.g. turn down the

potentiometer, setpoint selection via CAN).

• The motor can also be decelerated by the "Quick stop" function or by "DC-injection braking",

either directly requested by the user or as response to an error.

2. If the speed setpoint and the actual speed have fallen below the lower speed threshold or only

the speed setpoint has fallen below the lower speed threshold and the actual value monitoring

time has expired:

• For closing the brake, the bBrkReleaseOut trigger signal for triggering the power output is set

to FALSE.

• The bBrkReleased status signal is reset to FALSE.
• The brake application time starts to expire.

3. After the brake application time has expired, the controller is inhibited.

Time diagrams

[8-6]

Close holding brake in automatic mode via speed threshold (actual value = setpoint)

 Feedforward control

C02581/1

: Switching threshold

C02581/2

: Hysteresis for release

C02581/3

: Hysteresis for application

C02593/2

: Application delay

C02589/1

: Application time

Œ 

bBrkReleaseOut

0

0

bBrkReleased

CINH

t

t

t

t







0

nSpeedSetValue_a_

nSpeedSetValue_a

Œ

Œ Ž

Advertising