12

Function library

12.3

L_PCTRL_1

456

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.3.5

Control functions

The process controller has various digital inputs for controlling the FB:

Identifier

Data type

Information/possible settings

bIOff

BOOL

Switch off the I-component of the process controller

• Changes can be done online.

• Display parameter:

C00833/12

TRUE I-component of the process controller is switched off.

bInAct

BOOL

(from version 04.00.00)

Deactivate process controller temporarily (stop)

• Changes can be done online.

• Display parameter:

C00833/11

TRUE

• The current output value is frozen.

• The internal control algorithm is stopped.

• However, a setpoint selected via input nNSet_a is still provided in

operating modes 0/1/4/5.

bPIDOff

BOOL

(from version 04.00.00)

Reset the entire PID controller

• Display parameter:

C00833/41

TRUE

• The I component of the controller is set to zero.

• The controller output is set to zero.

• The internal control algorithm is stopped.