C01351 | acdrive: control word, C01351/1, 11 parameter reference – Lenze 8400 motec User Manual

Page 415

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

415

11

Parameter reference

11.2

Parameter list | C01351

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01351

Parameter | Name:

C01351 | ACDrive: Control word

Data type: UNSIGNED_16

Index: 23224

d

= 5AB8

h

From version 04.01.00

Display of the "AC Drive profile" control word for the 8400 motec

• If required, you can set an inversion for individual control bits in

C00890/1

which is included in this display.

• Detailed information on the "AC Drive Profile" can be found in the EtherNet/IP™ communication manual.

Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Run Forward

Connections between Run1 and Run2 and trigger events

can be found in the EtherNet/IP™ communication

manual.

Bit 1 Run Backward

Bit 2 Fault Reset

0->1 ≡ Reset error

0 ≡ No response

Bit 3 Reserved
Bit 4 Reserved
Bit 5 NetCtrl

Run/Stop control

0 ≡ Run/Stop control via local setting in the device or

terminal

1 ≡ Run/Stop control via network (e.g. from the scanner)

Bit 6 NetRef

Status of the reference speed / reference torque

0 ≡ Reference via local setting in the device or terminal

1 ≡ Reference via network (e.g. from the scanner)

Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved

Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved

Subcodes

Info

C01351/1

ACDrive: Control word

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Advertising