1 wdrivecontrol control word, Wdrivecontrol control word, Ee the – Lenze 8400 motec User Manual

Page 211: Subcha, 7technology applications

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

211

7

Technology applications

7.2

TA "Actuating drive speed"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.2.2.1

wDriveControl control word

In the control mode "40: Network (MCI/CAN)", the controller is controlled by a master control (e.g.

IPC) via the wDriveControl control word.

• The process data word received from the master control is provided to the application via the

upstream port block

LP_Network_In

at the wDriveControl input.

• Display parameter:

C00136/1

• The bit assignment of the control word can be obtained from the following table:

Motor control
bHeatSinkWarning

BOOL

TRUE Heatsink overtemperature detected

bOVDetected

BOOL

TRUE Overvoltage detected

bDcBrakeOn

BOOL

TRUE

DC-injection braking

active

bFlyingSyncActive

BOOL

TRUE

Flying restart function

is executed

nMotorFreqAct_a

C00058

| INT

Current field frequency

• Scaling: 16384 ≡ 327.68 Hz (24000 ≡ 480.00 Hz)

nOutputSpeedCtrl_a

INT

Speed or slip controller output

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

nMotorSpeedAct_a

C00051

| INT

Actual speed value

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

nMotorVoltage_a

INT

Current motor voltage/inverter output voltage

• Scaling: 16384 ≡ 1000 V

nDCVoltage_a

INT

Actual DC-bus voltage

• Scaling: 16384 ≡ 1000 V

nMotorCurrent_a

INT

Current motor current

• Scaling: 16384 ≡ 100 % I

max_mot

(

C00022

)

nMotorTorqueAct_a

C00056/2

| INT

Actual torque

• With "VFC (+encoder)" motor control, this value is determined from the current

motor current and corresponds to the actual torque only by approximation.

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

nHeatsinktemperature_a

INT

Heatsink temperature

• Scaling: 0 ... 16384 ≡ 0 ... 80 °C

• At sub-zero temperatures, the value "0" is output.

Holding brake control

• For a detailed function description see chapter entitled "

Holding brake control

".

bBrkReleaseOut

BOOL

Trigger signal for the motec-internal power output (terminals BR1 and BR2) for

triggering the brake.

• Use bit 0 in

C02582

to activate inverted triggering of the power output.

Functional settings

FALSE Apply brake.

TRUE Release brake.

bBrkReleased

BOOL

"Brake released" status signal considering the brake release time

• When the holding brake is triggered to close, bBrkReleased is immediately set to

FALSE even if the brake closing time has not yet elapsed!

TRUE Brake released (after the brake release time has expired).

Identifier

Data type

Value/meaning

Advertising