C00034 | ainx: configuration, C00036 | dcb: current, C00039 | fixed setpoint x (l_nset_1 n-fix) – Lenze 8400 motec User Manual

Page 341: C00039/1, C00039/2, C00039/3, Is used a, C00036, Is injecte, C00034/1

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

341

11

Parameter reference

11.2

Parameter list | C00034

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00034

C00036

C00039

Parameter | Name:

C00034 | AINx: Configuration

Data type: UNSIGNED_8

Index: 24541

d

= 5FDD

h

Configuration of the analog input for current or voltage measurement

Analog terminals

Selection list

Info

0 0...+10 V(-10V...+10V)

Input signal is voltage signal 0 V ... +10 V

• 0 V ... +10 V ≡ 0 % ... +100 %

1 0...+20mA

With external load resistor (250 Ohms):

Input signal is the current signal 0 mA ... 20 mA

• 0 mA ... 20 mA ≡ 0 % ... +100 %

2 4...+20mA

With external load resistor (250 Ohms):

Input signal is the current signal 4 mA ... 20 mA

• 4 mA ... 20 mA ≡ 0 % ... +100 %

• The current loop is monitored for open circuit

(I < 4 mA) by the device.

3 AIn1 - AIn2

Voltage difference (-10 V ... +10 V) between input AIn1

and input AIn2

• Selection is only sensible when using an

E84DGFCXxNx Communication Unit (no fieldbus;

extended terminal design).

Subcodes

Lenze setting

Info

C00034/1

0: 0...+10 V(-10V...+10V)

AIN1: Config.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00036 | DCB: Current

Data type: INTEGER_16

Index: 24539

d

= 5FDB

h

Braking current in [%] based on rated device current (

C00098

)

DC-injection braking

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

%

100.0 50.0 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00039 | Fixed setpoint x (L_NSet_1 n-Fix)

Data type: INTEGER_16

Index: 24536

d

= 5FD8

h

The

L_NSet_1

FB: Fixed speed setpoints (JOG values) for the setpoint generator

Setting range

(min. value | unit | max. value)

-199.9

%

199.9

Subcodes

Lenze setting

Info

C00039/1

40.0 %

Fixed setpoint 1

C00039/2

60.0 %

Fixed setpoint 2

C00039/3

80.0 %

Fixed setpoint 3

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Advertising