3 user-defined terminal assignment, User-defined terminal assignment, 6i/o terminals – Lenze 8400 motec User Manual

Page 191

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

191

6

I/O terminals

6.3

User-defined terminal assignment

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.3

User-defined terminal assignment

In order to individually adapt the preconfigured assignment of the input/output terminals to your

application, you can choose one of the following procedures:

A. In the »Engineer«:

• Change the terminal assignment on the Terminal assignment tab.
• Change the signal assignment on the Application Parameters tab, on the dialog level Over-

viewSignal flow.

B. In the »Engineer« or with the keypad:

• Change the parameters for signal configuration in the parameters list.

Tip!
First set a suitable Lenze configuration by selecting a corresponding control mode in

C00007

.

We recommend using the »Engineer« for the implementation of comprehensive user-de-

fined drive solutions.

Note!

If you change the preconfigured assignment of the digital and analog input/output ter-

minals, the terminal assignment will be a user-defined one. In

C00007

, control mode "0:

Interconnection changed" will be shown.
If you select a different control mode in

C00007

, all configuration parameters (

C00620/

x

,

C00621/x

,

C00700/x

and

C00701/x

) are reset to the Lenze default setting for the se-

lected control mode. This also applies if the 8400 motec is parameterised via DIP switch-

es.

Pre-assignment of the application

( 220)

Advertising