C02589 | holding brake: time system, C02593 | holding brake: activation time, C02589/1 – Lenze 8400 motec User Manual

Page 424: C02589/2, C02593/1, C02593/2, C02589, Deactivated, 11 parameter reference

Advertising
background image

11

Parameter reference

11.2

Parameter list | C02589

424

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02589

C02593

Bit 7  Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C02582 | Holding brake: Setting

Data type: UNSIGNED_8

Index: 21993

d

= 55E9

h

Parameter | Name:

C02589 | Holding brake: Time system

Data type: UNSIGNED_16

Index: 21986

d

= 55E2

h

Operating times of the holding brake

• The electromechanical delay times of the holding brake are specified in the data sheets or on the holding brake

nameplate.

Holding brake control

Setting range

(min. value | unit | max. value)

0

ms

60000

Subcodes

Lenze setting

Info

C02589/1

100 ms

Holding brake: Application time

• Time in which the holding brake is completely applied

from the beginning of control and in which the

controller is inhibited.

C02589/2

100 ms

Holding brake: Release time

• Time in which the holding brake is completely

released from the beginning of control.

C02589/3

0 ms

Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02593 | Holding brake: Activation time

Data type: UNSIGNED_32

Index: 21982

d

= 55DE

h

Time parameter for the delay of trigger signals of the holding brake control

Holding brake control

Setting range

(min. value | unit | max. value)

0.0

s

3600.0

Subcodes

Lenze setting

Info

C02593/1

0.0 s

Holding brake: Actual value monitoring

• Time in which the actual value is supposed to reach

the threshold for closing the brake if the setpoint has

already reached the threshold.

• Time > 0 s: If the actual speed value has not reached

the threshold within the time for brake application,

the holding brake is applied by control.

• Time = 0 s: The brake is only applied by control when

the actual speed has reached the application

threshold.

C02593/2

0.0 s

Holding brake: Application delay

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Advertising