12 function library – Lenze 8400 motec User Manual

Page 475

Advertising
background image

Lenze · 8400 motec · Reference manual · DMS 4.1 EN · 08/2013 · TD05

475

12

Function library

12.11

L_JogCtrlExtension_1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Parameter

Identifier

Data type

Value/meaning

bRfgOut

BOOL

Control signal for ramping down the ramp function generator in the FB

L_NSet_1

• Required configuration:

C00701/12

= "205: L_JogCtrlExtension_1: bRfgOut"

bJog1Out

bJog2Out

BOOL

Control signals for setting fixed speeds in the FB

L_NSet_1

• Required configuration:

C00701/6

= "206: L_JogCtrlExtension_1: bJog1Out"

C00701/7

= "207: L_JogCtrlExtension_1: bJog2Out"

Parameter

Possible settings

Info

C00488/1

InputSens.SlowDown1

• Selection of edge or level for

starting slow-down function 1

0 Level
1 Edge

C00488/2

InputSens.Stop1

• Selection of edge or level for stop

function 1

0 Level
1 Edge

C00488/3

InputSens.SlowDown2

• Selection of edge or level for

starting slow-down function 2

0 Level
1 Edge

C00488/4

InputSens.Stop2

• Selection of edge or level for stop

function 2

0 Level
1 Edge

C00488/5

InputSens.SlowDown3

• Selection of edge or level for

starting slow-down function 3

0 Level
1 Edge

C00488/6

InputSens.Stop3

• Selection of edge or level for stop

function 3

0 Level
1 Edge

Note!

If the bSlowDown-/bStop-inputs are configured edge-sensitively and a positioning has

been carried out, at least one of the two selection inputs (bInputSel1, bInputSel2) has to

change its state before a new positioning can be started!