H3C Technologies H3C Intelligent Management Center User Manual

Page 441

Advertising
background image

427

of the application in the dependency topology. APM automatically adds the dependencies

between Exchange Server 2007 and operating system applications by IP address and
displays their dependencies in the application topology.

{

Detect Application—Select this parameter if you want to enable application detection. APM
verifies the application connectivity by using the previous parameter settings, and adds the

application monitor only when it can connect to the application. If you do not select this

parameter, APM adds the application monitor without verifying the application connectivity.

5.

Click OK.

Modifying an Exchange Server 2007 application monitor

Authorized users can modify all parameters except the IP address of an Exchange Server 2007

application monitor. If the IP address of a monitored Exchange Server 2007 changes, add a new
application monitor for the host. The new application monitor cannot inherit the history data from the

previous application monitor.
To modify an Exchange Server 2007 application monitor:

1.

Click the Resource tab.

2.

From the navigation tree, select Application Manager > Application Monitor.
The application monitor list page appears.

3.

Click the Modify icon

for the Exchange 2007 application monitor you want to modify.

The page for modifying the Exchange Server 2007 application monitor appears.

4.

Modify the following parameters for the application monitor:

{

IP Address—Cannot be modified.

{

Name—Enter a unique application monitor name. H3C recommends naming the application
monitor as Application name_host IP address.

{

Use Template—Select Enable or Disable from the list.

{

Template—Click the

Configure link next to the Template field to select an existing template.

The Template field is automatically populated with the name of the selected template. For more

information about configuring application templates, see "

6 Configuration management

." This

field appears only when you select Enable from the Use Template list.

{

Description—Enter a description for the application monitor.

{

Traffic Collection Port—Enter one or more comma-separated service port numbers for Exchange
Server 2007. This field appears only when at least one probe is configured for APM and is

available only when you select Disable from the Use Template list.

{

Polling Interval (min)—Select a polling interval for the application monitor. Available options
include 1, 2, 3, 4, 5, 10, 20, and 30. The default polling interval is 5 minutes. A shorter polling

interval provides more accurate real-time data but consumes more system resources. This field is
available only when you select Disable from the Use Template list.

{

Username/Password—Enter the username and password of the Exchange Server 2007
administrator. The fields are available only when you select Disable from the Use Template list.

{

Contact—Enter the contact information, such as name, email address, and telephone number.
The default is the username of the operator who created the application monitor. This field is

available only when you select Disable from the Use Template list.